SMAC-MD

Breadcrumb

  • Home
  • Documents
  • Strong Motion Instruments
  • SMAC-MD
Submitted by: smoman
on Thu, 01/28/2021 - 13:41
Maker Akashi Corp.
Developed in 1988
Sensor type V401 (force-balanced feedback)
A/D converter 16-bit
Sampling frequency 50, 100 Hz
Amplitude range ±1 G
Frequency range 0.02 ~ 30 Hz
Trigger level 0.5 ~ 32 cm/s2
Pre-trigger time 10 sec.
Post-trigger time 15 ~ 99 sec.
Number of channels 3 (max. 9)
Dimensions and weight W40 cm x D42 cm x H21 cm, 20 kg